Dear MARMAM community,
My coauthors and I are excited to announce our recent paper on hormone analyses in small blubber samples (50 mg) of gray and fin whales published in Frontiers in Marine Science. It is open access and can be found here:
https://www.frontiersin.org/articles/10.3389/fmars.2021.808764/full
Wittmaack C, Urbán Ramírez J, Bernot-Simon D, Martínez-Aguilar S, Subbiah S, Surles JG, Looney M, Kumar N, Halaska B, Duignan PJ, Knauss M, Burns K and Godard-Codding CAJ (2022). Small Blubber Samples (50 mg) Sufficient for Analyses
of 10 Stress and Reproductive Steroid Hormones in Gray and Fin Whales via Liquid Chromatography Mass Spectrometry. Front. Mar. Sci. 8:808764.
doi: 10.3389/fmars.2021.808764
ABSTRACT
Information on stress, reproductive fitness, and health is difficult to obtain in wild
cetaceans but critical for conservation and management. The goal of this study was to
develop a methodology requiring minimal blubber mass for analysis of reproductive and
stress steroid hormones and, hence, suitable for cetacean biopsies. Blubber biopsies
and samples were collected from free-ranging and stranded gray and fin whales. Steroid
hormones were extracted from blubber samples as small as 50 mg using liquid-liquid
extraction methodology developed to handle the high fat content of blubber.
Samples were analyzed via liquid chromatography with tandem mass spectrometry
for 10 hormones: aldosterone, androstenedione, cortisol, cortisone, corticosterone,
17b-estradiol, estrone, 17a-hydroxyprogesterone, progesterone, and testosterone. As
part of the optimization, homogenization via bead beating and blade dispersion were
compared, and the former found superior. To investigate optimal yet minimal tissue mass
required, hormone panels were compared among paired 50, 150, and 400 mg samples,
the latter two being commonly reported masses for hormone blubber analysis. Results
indicated that 50 mg of blubber was suitable and sometimes superior. Additionally,
significant differences in precision values were observed between species, possibly
stemming from differences in blubber composition, and relevant to homogenization
technique selection and calibration methods that use blubber matrix matches obtained
from a species other than the study species. Based on recovery and precision values,
our methodology was accurate and precise in the measurement of spiked known
quantities for all 10 hormones, confirming the methodology capabilities in 50 mg blubber
mass in both species. Altogether, and in our specific sample sets, all endogenous
hormones, except corticosterone, were identified above the detection limit in 50 mg gray
whale blubber samples while all endogenous hormones, except aldosterone, cortisone,
Please feel free to contact me at celine.godard@ttu.edu
Best,
Céline Godard-Codding
*****************************************************************
Céline Godard-Codding, Ph.D.
Professor and Associate Chair
Department of Environmental Toxicology
The Institute of Environmental and Human Health
Texas Tech University and TTU Health Sciences Center
Box 41163
Lubbock, Texas 79409-1163
Office: (806)-834-2737
Fax: (806)-885-2132
FEDEX shipping address:
The Institute of Environmental and Human Health (TIEHH)
Reese Technology Center Building 555
1207 S. Gilbert Drive
Lubbock TX 79416-2103
*****************************************************************